Analysis of several causes of hoisting motor burning

1. In addition to lack of phase, there are other reasons for burning the motor
 
 
A. The load is too heavy;
 
B. Damaged motor bearings;
 
C. The brake is not working. When it is running, is it disconnected or the electromagnetic coil is not in good contact, which sometimes causes power failure and locks the brake drum.
 
2. Reasons for lack of phase:
 
A. The contactor contacts start frequently and ablate quickly. The contact leaf springs and the plastic deformation at the contact point will make the contact position insufficient and cause phase loss.
 
B. The fuse is too small, causing the heating to burn out the missing phase;
 
C. Poor power contact causes phase loss;
 
D. Poor contact of motor inlet.
 
E. Install automatic air circuit breaker and thermal overcurrent protector with high sensitivity, and install phase-deficient controller can effectively prevent it.
 
3. The lack of phase protector is very effective in protecting the lack of phase
 
Once the phase is missing, it can immediately open the contactor, the price is not expensive, generally only within 40--50 yuan. The set of normally closed contacts of the original control circuit start line is completed.